Manufacturer: |
PCE Instruments
|
Supplier number: | PCE-RCM 10 |
UPC: | 4250348717092 |
Technical specs:
- Display 2.4" LC color display
- Display resolution 240 x 320 pixels
- Power supply USB 5 V
- Battery type 1000 mAh
- Battery life 5 h in continuous measuring mode
- Charging time 2 h when the device is switched off
- Interface USB
- Ambient conditions 0 ... +50 °C
- Storage conditions -10 ... +60 °C
Particle measurement - Particle size channels PM 2.5 / PM 10
- Particle concentration 0 ... 2000 µg/m³
- Accuracy 30%
- Resolution 1 µg/m³
- Temperature Measuring range -20 ... +70 °C
- Accuracy ±1 °C
- Resolution 0.1 °C
Humidity Measuring range 0 ... 100 % r.H.
Accuracy - ±3.5 % r.h. (20 ... 80 % r.h.)
- ±5 % r.H. (0 ... 20 % r.H. / 80 ... 100 % r.H.)
- Resolution 0.1 % r.h.
PCE Instruments Particle Counter, PCE-RCM 10, 4250348717092 The air quality meter PCE-RCM 10...more
PCE Instruments Particle Counter, PCE-RCM 10, 4250348717092
The air quality meter PCE-RCM 10 measures dust loads in the magnitudes PM 2.5 and PM 10. The measured values of the air quality meter are shown on a brilliant color display. The fine dusts measured by the air quality meter PCE-RCM 10 are respirable in the order of magnitude PM 2.5, can deposit there and damage the lungs.
The air quality meter is very well suited for orienting measurements at possibly dust polluted workplaces. The measured values are shown on the color display in the colors green through yellow and red to pink. This traffic light function" of the air quality meter makes it easy to recognize the limit values and gives the possibility to react quickly to the change. With the setting "graphical display of measured values" you can view the changes in measured values over a period of 3 minutes.
The air quality meter PCE-RCM 10 measures dust loads in the magnitudes PM 2.5 and PM 10. The measured values of the air quality meter are shown on a brilliant color display. The fine dusts measured by the air quality meter PCE-RCM 10 are respirable in the order of magnitude PM 2.5, can deposit there and damage the lungs.
The air quality meter is very well suited for orienting measurements at possibly dust polluted workplaces. The measured values are shown on the color display in the colors green through yellow and red to pink. This traffic light function" of the air quality meter makes it easy to recognize the limit values and gives the possibility to react quickly to the change. With the setting "graphical display of measured values" you can view the changes in measured values over a period of 3 minutes.
- Air Quality Meter PCE-RCM 10 Air Quality Meter for Dust Pollution Measurement
- PM 2,5 and PM 10
- Traffic light function
- Graphical display
- Battery and mains operation
- Measurement of temperature and humidity
- 1 x Particle counter PCE-RCM 10
- 1 x USB cable
- 1 x instruction manual
Restrictions
>
WARNING: Cancer and Reproductive Harm. For more information go to: www.P65Warnings.ca.gov
Hazardous material
PC-842
You will receive your personal $15 voucher with your order confirmation
Spend over $200 and get a $15 voucher for your next order
$15
$249.30 *
$354.01 *
(29.58% Saved)
Free shipping!
Delivery time 3-5 business days
Secure payment
PCE Instruments Particle Counter, PCE-RCM 10
Add this item and enjoy fast shipping
Popular product! About people already have it in their shopping cart
Free SHIPPING - Directly from the manufacturer!
Top seller in the store!
Proven product
Top international brands already trust us!
Secure shopping
- Free shipping from $50
- Fast delivery
- Your personal buyer protection
Manufacturer: |
PCE Instruments
|
Supplier number: | PCE-RCM 10 |
UPC: | 4250348717092 |
Technical specs:
- Display 2.4" LC color display
- Display resolution 240 x 320 pixels
- Power supply USB 5 V
- Battery type 1000 mAh
- Battery life 5 h in continuous measuring mode
- Charging time 2 h when the device is switched off
- Interface USB
- Ambient conditions 0 ... +50 °C
- Storage conditions -10 ... +60 °C
Particle measurement - Particle size channels PM 2.5 / PM 10
- Particle concentration 0 ... 2000 µg/m³
- Accuracy 30%
- Resolution 1 µg/m³
- Temperature Measuring range -20 ... +70 °C
- Accuracy ±1 °C
- Resolution 0.1 °C
Humidity Measuring range 0 ... 100 % r.H.
Accuracy - ±3.5 % r.h. (20 ... 80 % r.h.)
- ±5 % r.H. (0 ... 20 % r.H. / 80 ... 100 % r.H.)
- Resolution 0.1 % r.h.
PCE Instruments Particle Counter, PCE-RCM 10, 4250348717092 The air quality meter PCE-RCM 10...more
PCE Instruments Particle Counter, PCE-RCM 10, 4250348717092
The air quality meter PCE-RCM 10 measures dust loads in the magnitudes PM 2.5 and PM 10. The measured values of the air quality meter are shown on a brilliant color display. The fine dusts measured by the air quality meter PCE-RCM 10 are respirable in the order of magnitude PM 2.5, can deposit there and damage the lungs.
The air quality meter is very well suited for orienting measurements at possibly dust polluted workplaces. The measured values are shown on the color display in the colors green through yellow and red to pink. This traffic light function" of the air quality meter makes it easy to recognize the limit values and gives the possibility to react quickly to the change. With the setting "graphical display of measured values" you can view the changes in measured values over a period of 3 minutes.
The air quality meter PCE-RCM 10 measures dust loads in the magnitudes PM 2.5 and PM 10. The measured values of the air quality meter are shown on a brilliant color display. The fine dusts measured by the air quality meter PCE-RCM 10 are respirable in the order of magnitude PM 2.5, can deposit there and damage the lungs.
The air quality meter is very well suited for orienting measurements at possibly dust polluted workplaces. The measured values are shown on the color display in the colors green through yellow and red to pink. This traffic light function" of the air quality meter makes it easy to recognize the limit values and gives the possibility to react quickly to the change. With the setting "graphical display of measured values" you can view the changes in measured values over a period of 3 minutes.
- Air Quality Meter PCE-RCM 10 Air Quality Meter for Dust Pollution Measurement
- PM 2,5 and PM 10
- Traffic light function
- Graphical display
- Battery and mains operation
- Measurement of temperature and humidity
- 1 x Particle counter PCE-RCM 10
- 1 x USB cable
- 1 x instruction manual
Restrictions
>