carte-bleue Hardware Software Agrar Bau und Handwerk dhl dpd Elektronik und Elektrotechnik fax Hotel Gastronomie Betriebs und Lagerausstattung Arbeitsschutz gls hermes Haus und Gebaeudetechnik hook storno cog Industriebedarf info mail mastercard notepad Buerobedarf ok paiement_d_avance_icon paypal phone rechnung sale search sofortueberweisung tnt ups visa Vorkasse Pagamento anticipato Vooruitbetaling iDeal voucher Warenkorb
Checkout
saved
Free
Shipping
saved

Maruson Technology 2000VA Online Rack Mount Uninterruptible Power Supply Unit, 8 Outlets, ULT-P2KRT

  • Topology: Online double-conversion

    INPUT
  • Voltage: 100 / 110 / 115 / 120 / 127Vac
  • Voltage Range: 55 - 150Vac +/- 5% at 50% load, 80 - 150Vac +/- 5% at 100% load
  • Frequency: 40 - 70Hz
  • Inlet: NEMA 5-20P, 20A T-blade plug

    OUTPUT
  • Output Voltage: 100 / 110 / 115 / 120 / 127Vac
  • Frequency Range (on Battery): 50 / 60 Hz +/- 1%
  • Output Voltage: 100 / 110 / 115 / 120 / 127Vac
  • Current Crest Ratio: 3:1 (max)
  • Harmonic Distortion: <2% THD (linear load), <4% THD (non-linear load)
  • Wave Form (on Battery): Sine wave
  • Outlet: 8 x NEMA 5-15/20R

    TRANSFER TIME
  • Line to Battery: 0ms
  • Inverter to Bypass: 4ms (typical)

    EFFICIENCY
  • AC Mode: 91%
  • Battery Mode: 90%
  • ECO Mode: 96%

    BATTERY
  • Chemistry: Sealed lead-acid
  • Quantity & Size: 4 x 12V / 9Ah (optional 6 x 12V / 7Ah for custom orders)
  • Charging Voltage: 54.8 Vdc +/- 1% (82.1Vdc at 6 x 12V / 7Ah)
  • Charging Current: 2A - 8A (adjustable)
  • Recharge Time: 3 hours to 95% capacity for internal batteries at 2A charging current

    PROTECTION
  • Emergency Power Off (EPO): Yes
  • Overload Protection: Yes
  • Overcharge Protection: Yes
  • Network / Phone / Fax Surge Suppression: Yes, RJ-11/45 combo ports (1-in, 1-out)
  • Surge Suppression: Yes
  • EMI / RFI Filter: Yes, full time

    ADDITIONAL FEATURES
  • Add-On External Battery Banks: Yes, up to three battery banks (model # ULT-P2KRTBB) may be used with this model
  • Programmable Outlets: Yes
  • ECO Mode: Yes
  • Advanced ECO Mode: Yes
  • Frequency Converter Mode: Yes, however using will derate UPS capacity by 40%

    COMMUNICATION
  • USB Port: Yes, for power management software to control and monitor the UPS conditions
  • RS232 Port: Yes, for power management software to control and monitor the UPS conditions
  • Software: Compatible with Windows 10/8/7/ Server 2012 R2 / 2008 R2 / Linux 32-Bit / 64-Bit / mac 10.6 to 10.11
  • Intelligent Slot: Yes, for use with add-on remote power management network card (model #SNMP-2)

    STATUS INDICATORS
  • LCD Screen: Yes, for Input/Output Voltages, Battery Level, Fault, status codes, and more
  • Audible Alert: Yes

    WARRANTY
  • Warranty: 2-Year Equipment and Connected Equipment Warranties. 2-Year: Battery Warranty. See Terms of Use and Warranty pages for additional information.

    PHYSICAL
  • Color: Black
  • Form Factor: Rack / tower convertible
  • Product Dimensions (DWH): 20.1 x 17.2 x 3.5 in / 510 x 438 x 88 mm
  • Product Weight: 43.0 lb / 19.5 kg

    Product specifications are subject to change without further notice. We assume no responsibility, and disclaims all liability, for any damages that may result from the use of this information or for any errors or omissions. Battery backup time varies with equipment, configuration, battery age, temperature, etc.
Maruson Technology 2000VA Online Rack Mount Uninterruptible Power Supply Unit, 8 Outlets,...more
Maruson Technology 2000VA Online Rack Mount Uninterruptible Power Supply Unit, 8 Outlets, ULT-P2KRT, 851484006671

Capacity: 2000VA / 1930W
Topology: Online double-conversion
Wave Form: Sine wave
Outlets: 8

Features:
  • 0.96 power factor
  • Zero transfer time from Line to Battery
  • Adjustable charging current up to 8A
  • Expandable runtime
  • Load segment control
  • 50/60Hz Frequency Converter Mode
  • Emergency Power Off (EPO)
  • ECO and Advanced ECO Modes
The UltimaPro RT series delivers reliable double-conversion online design with 0.96 power factor for energy efficiency to mission-critical loads. Zero transfer time and true sine wave offers an extraordinary battery backup system in rack mount form factor. With option to add-on external battery modules, this UPS battery runtime can be expanded as needed to meet your equipment needs with up to four add-on external battery banks.

Typical Applications:
  • Mid-size servers
  • ATMs
  • Lab equipment
  • Networking devices
  • Surveillance systems
  • VoIP / PBX systems
  • Security systems
  • Gaming computers
  • Slot machines
Main Features:

(8) Battery-Backed Outlets with Surge Suppression
These outlets keep critical electronics online during a temporary blackout, adjust minor voltage fluctuations, and offer protection from power surges and voltage spikes. If a blackout occurs or a power disruption beyond the tolerance range is detected, the UPS will switch over to battery power and supply these outlets with power. Connect mission-critical electronics to these outlets.

True Double-Conversion Online Topology
The main supply is fed directly into the UPS and charges batteries within the UPS. The battery power is then converted back to the main power to feed the protected equipment. Due to these two conversions, this UPS type is often known as a Double-Conversion UPS.

Zero Transfer Time
True online double-conversion topology for zero transfer time from Line Mode to Battery Mode in case of a power disturbance prevents malfunction of mission-critical equipment.

Pure Sine Wave Output
Best waveform for sensitive electronics.

Benefits include:
  • Smoother waveform
  • Best for sensitive equipment
  • Higher quality than a modified sine wave
  • Maintains voltage at a safe level
  • Motors run at their intended speed and with less heat
  • Equipment runs with less noise
  • IT equipment lasts longer
  • Low harmonic distortion
Overload Protection
Protects the UPS from an overload. If the circuit breaker trips, unplug a few electronics before resetting the circuit breaker and turning your unit back on.

0.96 Power Factor
A high power factor rating offers efficient loading of the power supply. It maximizes energy efficiency to cut down on energy cost and energy loss by reducing the load on transformers and distribution equipment.

Emergency Power Off (EPO) Tab
Instantly shut off the UPS and prevent the UPS from supplying power in the event of an emergency.

Load Segment Control
Control grouped outlets allows better management of battery power by prioritizing mission-critical devices by manual or pre-setting. This allows mission-critical devices to have longer backup time than non-mission-critical devices.

Expandable Battery Runtime
Add up to 3 external battery banks to extend the battery runtime of your UPS.

2A to 8A Adjustable Battery Charger
Select between 2A to 8A battery charging current for faster battery recharge time depending on the number of external battery modules connected to the UPS. This is especially useful if located in an area with frequent power disturbances that would cause the UPS to run on Battery Mode frequently.

Hot Swappable Batteries
Replace batteries without shutting off the UPS to avoid downtime.

Power Management Software
Monitor and control the UPS from your computer with the included user-friendly software to automate computer shutdown, monitor battery levels, set UPS parameters, receive alerts of abnormalities, and more.

50/60Hz Frequency Converter Mode
Select 50Hz or 60Hz output frequency best suited for connected equipment. It is especially helpful when used to help regulate the speed of motorized equipment to match the frequency.

NOTE: If input frequency is 60Hz, setting the UPS output frequency to 50Hz will derate the UPS capacity by 40%.

Rack / Tower Convertible
Install the UPS in vertically or horizontally.

EMI / RFI Filter
EMI / RFI filter suppresses electromagnetic noise and radio frequency interference transmitted from AC power.

ECO and Advanced ECO Modes
Efficiency Corrective Optimizer (ECO) improves energy consumption by changing how power flows through the UPS.

ECO Mode: Improves energy efficiency of the UPS by setting the UPS to "standby." Input power will bypass voltage to output when the input voltage is within the acceptable range. Power factor correction and the inverter are still active in this mode.

Advanced ECO Mode: Improves energy efficiency of the UPS by setting the UPS to "standby." Input power will bypass voltage to output when the input voltage is within the acceptable range. Power factor correction and the inverter are not active in this mode.

Cold Start Capable
Turn on the UPS even without utility power as long as there is sufficient battery power.

Auto-Restart During AC Recovery
Once power returns to normal and the battery levels are sufficient, the UPS will automatically restart.

Off-Mode Charging
The UPS continues charging the internal batteries when powered off as long as the unit is plugged into an AC mains wall socket.

LCD Screen
See real-time status information of your UPS power conditions including the voltages, battery level, fault detected, and more.

Enable / Disable Audible Alarm
Enable or disable the audible alert for your unit.

To enable or disable the audible alarm, turn the LCD screen on first then press the button twice quickly. The UPS will beep once the alarm is enabled. The default setting for the audible alarm is enabled. If the alarm is disabled, no audible alert will be made when the UPS reaches a low battery state.

Optional Accessories (Not Included)
  • Network Management Card - For remote power monitoring. See model number #SNMP-2 for compatibility with this UPS series.
  • Rail Kit - For installation to rack cabinets. See model # ULT-RMKIT123 for the compatible rail kit to this UPS.
  • Add-On External Battery Banks - Extend the battery runtime in the event of an extended power outage. See model # ULT-P2KRTKBB for compatibility with this UPS.
Warranty (US & Canada)
2-year equipment warranty, 2-year battery warranty, and 2-year connected equipment warranty with product registration.

WARNING:The batteries, battery posts, terminals, and related accessories can expose you to chemicals including lead and lead compounds, which are known to the State of California to cause cancer and birth defects, or other reproductive harm. Wash hands after handling. For more information, go to www.p65warnings.ca.gov.
Restrictions
>
WARNING: Cancer and Reproductive Harm. For more information go to: www.P65Warnings.ca.gov
Hazardous material
You will receive your personal $15 voucher with your order confirmation
Voucher
Spend over $200 and get a $15 voucher for your next order
$15 Voucher badge background image
$1,079.41 * $2,739.55 * (60.6% Saved)

plus VAT Free shipping

Free shipping!

Delivery time 10-15 business days

Type

Secure payment Secure payment
Maruson Technology 2000VA Online Rack Mount Uninterruptible Power Supply Unit, 8 Outlets, ULT-P2KRT
Maruson Technology 2000VA Online Rack Mount Uninterruptible Power Supply Unit, 8 Outlets, ULT-P2KRT
Add this item and enjoy fast shipping
Badge-Fire Popular product! About people already have it in their shopping cart
Badge-Package Free SHIPPING - Directly from the manufacturer!
Badge-Medal Top seller in the store!
Proven product
Proven product
Top international brands already trust us!
intel
Apple
John Deere
Netflix
Tesla
AT&T
cvs health
Caterpillar
Nike
Walmart
Secure shopping
Secure shopping
  • Free shipping from $50
  • Fast delivery
  • Your personal buyer protection
  • Topology: Online double-conversion

    INPUT
  • Voltage: 100 / 110 / 115 / 120 / 127Vac
  • Voltage Range: 55 - 150Vac +/- 5% at 50% load, 80 - 150Vac +/- 5% at 100% load
  • Frequency: 40 - 70Hz
  • Inlet: NEMA 5-20P, 20A T-blade plug

    OUTPUT
  • Output Voltage: 100 / 110 / 115 / 120 / 127Vac
  • Frequency Range (on Battery): 50 / 60 Hz +/- 1%
  • Output Voltage: 100 / 110 / 115 / 120 / 127Vac
  • Current Crest Ratio: 3:1 (max)
  • Harmonic Distortion: <2% THD (linear load), <4% THD (non-linear load)
  • Wave Form (on Battery): Sine wave
  • Outlet: 8 x NEMA 5-15/20R

    TRANSFER TIME
  • Line to Battery: 0ms
  • Inverter to Bypass: 4ms (typical)

    EFFICIENCY
  • AC Mode: 91%
  • Battery Mode: 90%
  • ECO Mode: 96%

    BATTERY
  • Chemistry: Sealed lead-acid
  • Quantity & Size: 4 x 12V / 9Ah (optional 6 x 12V / 7Ah for custom orders)
  • Charging Voltage: 54.8 Vdc +/- 1% (82.1Vdc at 6 x 12V / 7Ah)
  • Charging Current: 2A - 8A (adjustable)
  • Recharge Time: 3 hours to 95% capacity for internal batteries at 2A charging current

    PROTECTION
  • Emergency Power Off (EPO): Yes
  • Overload Protection: Yes
  • Overcharge Protection: Yes
  • Network / Phone / Fax Surge Suppression: Yes, RJ-11/45 combo ports (1-in, 1-out)
  • Surge Suppression: Yes
  • EMI / RFI Filter: Yes, full time

    ADDITIONAL FEATURES
  • Add-On External Battery Banks: Yes, up to three battery banks (model # ULT-P2KRTBB) may be used with this model
  • Programmable Outlets: Yes
  • ECO Mode: Yes
  • Advanced ECO Mode: Yes
  • Frequency Converter Mode: Yes, however using will derate UPS capacity by 40%

    COMMUNICATION
  • USB Port: Yes, for power management software to control and monitor the UPS conditions
  • RS232 Port: Yes, for power management software to control and monitor the UPS conditions
  • Software: Compatible with Windows 10/8/7/ Server 2012 R2 / 2008 R2 / Linux 32-Bit / 64-Bit / mac 10.6 to 10.11
  • Intelligent Slot: Yes, for use with add-on remote power management network card (model #SNMP-2)

    STATUS INDICATORS
  • LCD Screen: Yes, for Input/Output Voltages, Battery Level, Fault, status codes, and more
  • Audible Alert: Yes

    WARRANTY
  • Warranty: 2-Year Equipment and Connected Equipment Warranties. 2-Year: Battery Warranty. See Terms of Use and Warranty pages for additional information.

    PHYSICAL
  • Color: Black
  • Form Factor: Rack / tower convertible
  • Product Dimensions (DWH): 20.1 x 17.2 x 3.5 in / 510 x 438 x 88 mm
  • Product Weight: 43.0 lb / 19.5 kg

    Product specifications are subject to change without further notice. We assume no responsibility, and disclaims all liability, for any damages that may result from the use of this information or for any errors or omissions. Battery backup time varies with equipment, configuration, battery age, temperature, etc.
Maruson Technology 2000VA Online Rack Mount Uninterruptible Power Supply Unit, 8 Outlets,...more
Maruson Technology 2000VA Online Rack Mount Uninterruptible Power Supply Unit, 8 Outlets, ULT-P2KRT, 851484006671

Capacity: 2000VA / 1930W
Topology: Online double-conversion
Wave Form: Sine wave
Outlets: 8

Features:
  • 0.96 power factor
  • Zero transfer time from Line to Battery
  • Adjustable charging current up to 8A
  • Expandable runtime
  • Load segment control
  • 50/60Hz Frequency Converter Mode
  • Emergency Power Off (EPO)
  • ECO and Advanced ECO Modes
The UltimaPro RT series delivers reliable double-conversion online design with 0.96 power factor for energy efficiency to mission-critical loads. Zero transfer time and true sine wave offers an extraordinary battery backup system in rack mount form factor. With option to add-on external battery modules, this UPS battery runtime can be expanded as needed to meet your equipment needs with up to four add-on external battery banks.

Typical Applications:
  • Mid-size servers
  • ATMs
  • Lab equipment
  • Networking devices
  • Surveillance systems
  • VoIP / PBX systems
  • Security systems
  • Gaming computers
  • Slot machines
Main Features:

(8) Battery-Backed Outlets with Surge Suppression
These outlets keep critical electronics online during a temporary blackout, adjust minor voltage fluctuations, and offer protection from power surges and voltage spikes. If a blackout occurs or a power disruption beyond the tolerance range is detected, the UPS will switch over to battery power and supply these outlets with power. Connect mission-critical electronics to these outlets.

True Double-Conversion Online Topology
The main supply is fed directly into the UPS and charges batteries within the UPS. The battery power is then converted back to the main power to feed the protected equipment. Due to these two conversions, this UPS type is often known as a Double-Conversion UPS.

Zero Transfer Time
True online double-conversion topology for zero transfer time from Line Mode to Battery Mode in case of a power disturbance prevents malfunction of mission-critical equipment.

Pure Sine Wave Output
Best waveform for sensitive electronics.

Benefits include:
  • Smoother waveform
  • Best for sensitive equipment
  • Higher quality than a modified sine wave
  • Maintains voltage at a safe level
  • Motors run at their intended speed and with less heat
  • Equipment runs with less noise
  • IT equipment lasts longer
  • Low harmonic distortion
Overload Protection
Protects the UPS from an overload. If the circuit breaker trips, unplug a few electronics before resetting the circuit breaker and turning your unit back on.

0.96 Power Factor
A high power factor rating offers efficient loading of the power supply. It maximizes energy efficiency to cut down on energy cost and energy loss by reducing the load on transformers and distribution equipment.

Emergency Power Off (EPO) Tab
Instantly shut off the UPS and prevent the UPS from supplying power in the event of an emergency.

Load Segment Control
Control grouped outlets allows better management of battery power by prioritizing mission-critical devices by manual or pre-setting. This allows mission-critical devices to have longer backup time than non-mission-critical devices.

Expandable Battery Runtime
Add up to 3 external battery banks to extend the battery runtime of your UPS.

2A to 8A Adjustable Battery Charger
Select between 2A to 8A battery charging current for faster battery recharge time depending on the number of external battery modules connected to the UPS. This is especially useful if located in an area with frequent power disturbances that would cause the UPS to run on Battery Mode frequently.

Hot Swappable Batteries
Replace batteries without shutting off the UPS to avoid downtime.

Power Management Software
Monitor and control the UPS from your computer with the included user-friendly software to automate computer shutdown, monitor battery levels, set UPS parameters, receive alerts of abnormalities, and more.

50/60Hz Frequency Converter Mode
Select 50Hz or 60Hz output frequency best suited for connected equipment. It is especially helpful when used to help regulate the speed of motorized equipment to match the frequency.

NOTE: If input frequency is 60Hz, setting the UPS output frequency to 50Hz will derate the UPS capacity by 40%.

Rack / Tower Convertible
Install the UPS in vertically or horizontally.

EMI / RFI Filter
EMI / RFI filter suppresses electromagnetic noise and radio frequency interference transmitted from AC power.

ECO and Advanced ECO Modes
Efficiency Corrective Optimizer (ECO) improves energy consumption by changing how power flows through the UPS.

ECO Mode: Improves energy efficiency of the UPS by setting the UPS to "standby." Input power will bypass voltage to output when the input voltage is within the acceptable range. Power factor correction and the inverter are still active in this mode.

Advanced ECO Mode: Improves energy efficiency of the UPS by setting the UPS to "standby." Input power will bypass voltage to output when the input voltage is within the acceptable range. Power factor correction and the inverter are not active in this mode.

Cold Start Capable
Turn on the UPS even without utility power as long as there is sufficient battery power.

Auto-Restart During AC Recovery
Once power returns to normal and the battery levels are sufficient, the UPS will automatically restart.

Off-Mode Charging
The UPS continues charging the internal batteries when powered off as long as the unit is plugged into an AC mains wall socket.

LCD Screen
See real-time status information of your UPS power conditions including the voltages, battery level, fault detected, and more.

Enable / Disable Audible Alarm
Enable or disable the audible alert for your unit.

To enable or disable the audible alarm, turn the LCD screen on first then press the button twice quickly. The UPS will beep once the alarm is enabled. The default setting for the audible alarm is enabled. If the alarm is disabled, no audible alert will be made when the UPS reaches a low battery state.

Optional Accessories (Not Included)
  • Network Management Card - For remote power monitoring. See model number #SNMP-2 for compatibility with this UPS series.
  • Rail Kit - For installation to rack cabinets. See model # ULT-RMKIT123 for the compatible rail kit to this UPS.
  • Add-On External Battery Banks - Extend the battery runtime in the event of an extended power outage. See model # ULT-P2KRTKBB for compatibility with this UPS.
Warranty (US & Canada)
2-year equipment warranty, 2-year battery warranty, and 2-year connected equipment warranty with product registration.

WARNING:The batteries, battery posts, terminals, and related accessories can expose you to chemicals including lead and lead compounds, which are known to the State of California to cause cancer and birth defects, or other reproductive harm. Wash hands after handling. For more information, go to www.p65warnings.ca.gov.
Restrictions
>
WARNING: Cancer and Reproductive Harm. For more information go to: www.P65Warnings.ca.gov
Hazardous material
Questions about the article